Pobieranie prezentacji. Proszę czekać

Pobieranie prezentacji. Proszę czekać

Maciej Michno IBM Systems Engineer Mobile: 605 821 729.

Podobne prezentacje


Prezentacja na temat: "Maciej Michno IBM Systems Engineer Mobile: 605 821 729."— Zapis prezentacji:

1 Maciej Michno IBM Systems Engineer Mobile:

2 Agenda  Rodzina IBM Storwize  IBM SAN Volume Controller  IBM Storwize V7000 Gen2  IBM Storwize V5000  IBM Storwize V3700

3 Wirtualizacja Pamięci Masowych Backup, Recovery, Archiwum, Rozwiązania optymalizacyjne Centralne zarządzanie heterogenicznym środowiskiem pamięci masowych Inne macierze Serwery plików i systemy Unified Storage Area, CEE, & iSCSI Networks Brocade, CISCO, Juniper, BNT SAN Volume Controller (SVC) Non-IBM Tivoli Storage Manager (TSM) ProtecTIER - Deduplication Tivoli Productivity Center (TPC) DS8870 DS8870 V5000 V5000 DS3500 DS3500 XIV Gen3 XIV Gen3 Others HDS HP EMC Storwize V7000 Storwize V7000 Zintegrowane środowisko wirtualizacyjne Enterprise Midrange Entry Real-Time Compression Large Enterprise Entry–>Enterprise Systems Director – Storage Control SONAS N Series Pamięć blokowa Zielony backup i archiwum Taśmy DCS3860 DCS3860 V7000U Entry -> Low-Mid Opcja NAS V7000 IBM System Storage Portfolio Storwize V3700 Storwize V3700 Flash Sys Virtual Storage Center (VSC) 3

4 SAN Volume Controller 06/2003 Rodzina Storwize Storwize V7000 Unified 10/2011 Storwize V /2010 Storwize V /2012 Flex System V /2012  Wspólna platforma programowa (kod)  Spójny zestaw funkcjonalności  Zunifikowane zarządzanie (GUI i konsola) Storwize V /2013

5 Struktura logiczna 5

6 6 A2 A6 B1 B5 A3 A7 B2 B6 A4 A8 B3 B7 A1 A5 A9 B4 B8 A1A2A3A4A5A6A7A8 B1B2B3B4B5B6B7B8 A9 Volume A Volume B Volumes Managed Disks Thin Provisioned Volume C C1C2C3C4C5C6C7C8 C1 Storage Pool

7 Wirtualizacja pamięci masowych 7 Volume Storage Pool MDisks SCSI LUNs Kontroler RAID LUN 4LUN 3 LUN 2 LUN 1LUN 4LUN 3 LUN 2 LUN 1 MD 4MD 3 MD 2 MD 1MD 8MD 7 MD 6 MD 5 VD 4 VD 3 VD 2 VD 1 VD 7 VD 6 VD 5 Wirtualizator Szybkie Duże Kontroler RAID

8 Korzyści wirtualizacji – lepsza utylizacja przestrzeni dyskowej Tradycyjny SAN  Pojemność jest izolowana na wyspach SAN  Wiele punktów zarządzania  Niska utylizacja dysków SVC/ Storwize V7000 / V5000  Pojemność jako wspólny zasób  Lepsze wykorzystanie pojemności  Jeden punkt zarządzania SAN 25% 50% 95% SAN 55% Storwize V7000

9 SAN Ciągła migracja danych Tradycyjny SAN 1. Zatrzymanie aplikacji 2. Przeniesienie danych 3. Ponowne udostępnienie danych 4. Restart aplikacji Zwirtualizowane środowisko 1. Przenosimy dane  Host nie widzi przerwy w dostępie do danych SAN Storwize V7000

10 Uproszczenie administracji – serwisy kopiujące 10 Tradycyjna sieć SAN  Różne serwisy replikujące różne macierze  Macierz docelowa musi być tego samego typu co źródłowa  Tańsze macierze bez replikacji Wirtualizator Pamięci Masowej  Wspólne serwisy kopiujące i replikujące w całej sieci SAN niezależne od macierzy  Można replikować dane na macierze tańsze obniżając koszty replikacji 10 SAN FlashCopy® Metro/Global Mirror FlashCopy® Metro/Global Mirror TimeFinder SRDF IBM DS5000 EMC DMX EMC Clariion IBMHP EVA IBMHDS AMS wirtualizator

11 Volume Mirroring  Storwize przechowuje dwie kopie Volumenu  Jeśli jedna kopia przestanie działać Storwize umożliwia dostęp do danych z drugiej kopii Automatyczna resynchronizacja  Lokalne HA  Kopie mogą zostać rozdzielone Każda kopia może stać się produkcyjna Copy 0 Copy 1 Storwize V7000

12 Thin - Provisioning Wolność wyboru..  Wolumen w pełni zaalokowany  Wolumen „thin-prov” Swoboda zmiany..  Konwersja Thin na Full  Konwersja Full na Thin 12

13 Flash Copy Backup, Recovery, Testy, Kopie systemów  Kopie migawkowe (Snapshoty)  Kopie pełne (Clone)  Kopie przyrostowe (Backup)  Kopie kaskadowe (kopia z kopii) Do 256 Kopii 2. Reverse FlashCopy OR Source Target

14 Bezpieczeństwo danych System Dyskowy Vol0Vol0’ System Dyskowy System Dyskowy’ RWW Lokalny mirror Dwie niezależne kopie HA w obrębie lokalizacji Global Mirror  Replikacja asynchroniczna Metro Mirror  Replikacja synchroniczna FlashCopy  Migawki wolumenów  Kopie na inne systemy dyskowe Storwize V7000

15 Benefity optymalizacji - IBM Easy Tier Technologia, która się uczy Optymalizacja polegająca na umieszczeniu „gorących” danych na dyskach SSD Trójwarstwowy, w pełni automatyczny mechanizm optymalizacyjny Efekt: wzrost IOPS, spadek RT Hot-spotyZoptymalizowana wydajność Automatyczna relokacja SSD HDD SSD HDD

16 Easy Tier – automatyczna relokacja fragmentów danych na podstawie obciążenia Wolumen Logiczny Pula extentów Easy Tier SSD HDD Wirtualizacja – podział na extenty Dane „gorące” Dane „ zimne” Wolumeny logiczne

17 Easy Tier 3  Now supports two or three tiers –Flash + 2 disk tiers –Flash + 1 disk tier –2 disk tiers  Deploy flash and enterprise disk for performance  Grow capacity with low cost disk  Storwize V7000 moves data automatically between tiers  Available on all systems licensed for Easy Tier –No additional charge Flash Arrays HDD Arrays Active Data Migrates Up Less Active Data Migrates Down 17

18 Easy Tier 3 STAT Tool  Provides recommendations on adding additional tier capacity and performance impact –Tier 0: Flash –Tier 1: “Enterprise” disk (15K and 10K) –Tier 2: Nearline disk (7.2K)

19 Kompresja ► Kompresja jest zaimplementowana jako trzeci typ wolumenów ► Wspierane te same funkcje co dla Thin-Provisioning (takie jak autoexpand…) ► GUI wyswietla oszczedności wynikające z zastosowania kompresji

20 Współczynnik kompresji 20 Storage after Compression 0% 20% 40% 60% 80% 100% Bazy danych Dane użytkowników CAD/CAM Engineering Serwery wirtualne 2.5x mniej pojemności 6.6x szybsze backupy 3.3x szybsza replikacja 3.5x skrócenie RTOs 20% do 60% 85.0% 70.0% 72.0% Compression Ratio

21 Kompresja monitoring ► GUI wspiera rozdzielenie monitoringu CPU dla kompresji

22 Graficzny interfejs użytkownika (GUI)

23 New SVC Engine  More powerful hardware platform –2x performance of SVC CG8 engine –Up to 9x compressed performance  One or two 8-core CPUs  32GB cache per CPU (32GB or 64GB of cache per engine)  More flexible server connectivity  Industry first hardware compression acceleration with Intel QuickAssist technology –One or two optional accelerators –Provide dedicated processing power and greater throughput for compression  Integrated flash capability: up to 48 12Gbps flash drives –In external flash expansion enclosures 23

24 New SVC Engine  2145 Model DH8  New 2U form factor –Internal batteries eliminate need for UPS –Total system size unchanged  Up to 3 I/O adapter cards 8Gbps FC10Gbps FCoE/iSCSI1 Gbps iSCSI Expansion slots 1Gb iSCSI Technician IP port Dual PSUs 24

25 SVC Configuration Rules  At least one compression accelerator is required to use Real- time Compression  Optional second CPU and 32GB memory required –When using Real-time Compression –When 3 host interface cards are installed Three FC interface cards or two FC interface cards and one 10GbE card  Optional second CPU and memory may be installed now in anticipation of future use (see SODs)  Both engines in an I/O Group must be configured the same 25

26 New SVC Flash Expansion  One or two SVC SFF Expansion Enclosures – F –No other expansion enclosure supported  Attach to both nodes in an I/O Group –Requires 12Gbps SAS Enclosure attach card in both  Up to GB, 400GB, or 800GB 12Gbps flash drives –Up to 38.4TB raw capacity –Disk drives are not supported  Flash may be used for dedicated volumes or with Easy Tier 26

27 SVC Investment Protection  New SVC engines may be added to existing SVC systems without disruption  New SVC engines may replace existing engines in SVC systems without disruption  All engines in an SVC system may access flash expansion capacity  SVC system must be running Version 7.3 software 27

28 SVC Maximum Performance (One I/O Group) Uncompressed SVC CG8New SVC DH8 Read Hit IOPS 1,000,0001,500,000 Read Miss IOPS 360,000630,000 Write Miss IOPS 125,000200,000 “DB-like” 200,000385,000 Compressed SVC CG8New SVC DH8 Read Miss IOPS 2,600-50,00071, ,000 Write Miss IOPS 1,200-16,00028, ,000 “DB-like” 2,200-40,00059, ,000  Compressed performance shows a range depending on I/O distribution  Compressed performance is better than uncompressed in some cases because of fewer I/Os to drives and additional cache benefits Preliminary data: Subject to change before GA

29 New SVC Data Engine  Virtualized server environments demand virtualized storage  2x performance: up to 128 cores  50% more connectivity: up to 96 FC ports  2.5x cache: up to 512GB  6x integrated flash: up to 192 drives Power to Virtualize 29

30 New Storwize V7000  More powerful hardware platform –2x performance of previous Storwize V7000 –Compressed performance comparable or better than uncompressed previous Storwize V7000  More flexible server connectivity  Up to 8x cache: 32GB or 64GB cache per controller (64GB or 128GB per control enclosure)  Industry first hardware compression acceleration with Intel QuickAssist technology –One accelerator standard, second optional –Provides dedicated processing power and greater throughput for compression –Cache upgrade required when using second compression accelerator  Double scalability: Up to 20 expansion enclosures –Up to 504 SFF drives or 240 LFF drives per system –Up to 1056 SFF drives or 960 LFF drives per clustered system –12 Gbps SAS connectivity 30

31 New Storwize V7000 Control Enclosure  Available only in 2.5-inch drive model –  Flexible interface options  One standard, optional second compression accelerator  Technician IP port replaces USB key configuration Dual controller canisters Host interface slots Compression accelerator slot PSU SAS expansion ports 1GbE ports Technician IP port Ports per System 8Gbps FC10Gbps FCoE/iSCSI1 Gbps iSCSI

32 New Storwize V7000 Expansion Enclosure  Available in 2.5- and 3.5-inch drive models –2076 Models 12F and 24F  Attaches to new control enclosure using 12Gbps SAS  Mix drives within enclosure, including different drive speeds  Mix enclosure types in a system  All drives dual ported, hot swappable 2.5-inch Flash Drives 200GB, 400GB, 800GB Flash12Gbps 2.5-inch High Performance Drives 300GB, 600GB SAS, 15K RPM12Gbps 600GB, 900GB, 1.2TB SAS, 10K RPM6Gbps 1TB NL-SAS, 7.2K RPM6Gbps 3.5-inch High Capacity Drives 2TB, 3TB, 4TB NL-SAS, 7.2K RPM6Gbps 32

33 New Storwize V7000 Expansion  Up to 20 expansion enclosures per control enclosure  In a clustered system, software supports maximum of 1056 drives –Enables fully populated LFF system (4PB raw capacity) –Exceeds needs of almost all customers using SFF drives  Previous expansion enclosures and drives cannot attach to new control enclosures –Protect investments and migrate data by mixing old and new systems in a clustered system 33

34 New Storwize V7000  2x scalability: up to 4PB  2x performance: up to 64 cores  2x infrastructure speed: 12Gbps SAS  2x connectivity: up to 64 FC ports  8x cache: up to 512GB Power and Scalability for All Your Data 34

35 V7000 Unified – NAS V7000 Unified

36 Storwize Family Software Version 7.3  Supports new Storwize V7000 and new SVC engine  Supports additional expansion for Storwize V3700 and Storwize V5000 –Both systems now support up to 9 expansion enclosures  Easy Tier 3  Storage Pool Balancing  Improved licensing model for Storwize V7000 and Storwize V

37 IBM Storwize V7000  Storwize V7000 – nowoczesny system dyskowy klasy midrange. Posiada funkcjonalnośc wirtualizacji wewnętrznej i zewnętrznej przestrzeni dyskowej  Bazuje na technologii SVC  Wykonany w architekturze SAS  Pełna redundancja 8GB pamięci cache per kontroler– (per macierz 16GB pamięci cache)  Interfejsy dysków 8 portów 8 Gbps FC 4 porty 1 Gbps iSCSI 4 porty 10 Gbps iSCSI  Instalacja i wymiana komponentów u klienta  Wszystkie elementy są wymienialne na „gorąco”

38 Storwize V7000 – widok z przodu i z tyłu 10Gbps iSCSI/FCoE 1Gbps iSCSI 8Gbps FC Obudowa – 12 x 3.5” LFF /212 Obudowa – 24 x 2.5” SFF /224

39 Control Enclosures Półki kontrolerów Modularna budowa  Początek z półką kontrolerów Do 9 półek rozszerzeń na jedną parę kontrolerów Mieszanie półek 2.5” & 3.5” Mieszanie rodzajów dysków w ramach każdej półki  Możliwość dodawania kolejnych par kontrolerów

40 Storwize V7000 – dyski 2,5’’3,5’’ 146GB 15K2TB GB 15K3TB GB 10K 4TB GB 10K 900GB 10K 1.2TB 10K 1TB GB SSD 400GB SSD 800GB SSD

41 Storwize V Licencjonowanie Thin Provisioning FlashCopy Easy Tier Metro and/or Global Mirror – Opcjonalnie External Virtualization – Opcjonalnie Kompresja - Opcjonalnie

42 Obudowa Storwize V5000 o wysokości 2U:  2x kontroler (NOD)  16GB Cache w standardzie  Do 9 półek rozszerzeń  Do 240 dysków 2,5'' lub 120 dysków 3,5''  Do 480TB pojemności  Możliwość mieszania dysków HDD/SSD w obudowie  Poziomy RAID: 0, 1, 5, 6, 10 Storwize V Charakterystyka

43 Storwize V widok z przodu

44  2x port iSCSI 1Gb/s Ethernet  4x port SAS 6Gb/s  4x Fibre Channel 8Gb/s lub 2x 10Gbps iSCSI/FCoE Storwize V widok z tyłu Mgmt and 1Gbps iSCSI SAS Disk Expansion Ports 4x 8Gbit Fibre Channel SAS Host Attach PortsPower input cables

45 Półka rozszerzeń V widok z tyłu SAS Disk Expansion In Ports SAS Disk Expansion Out Ports Power input cables

46 Storwize V Łańcuch SAS Control Enclosure Chain 1 Expansion Enclosures Chain 2 Expansion Enclosures

47 Połączenie z hostami poprzez switch FC

48 Połączenie bezpośrednie z hostami po FC

49 Storwize Licencjonowanie Internal Virtualization Data Migration System Clustering Thin Provisioning FlashCopy – Opcjonalnie Easy Tier – Opcjonalnie Remote Mirroring – Opcjonalnie External Virtualization – Opcjonalnie

50 Obudowa Storwize V3700 o wysokości 2U:  2x kontroler (NOD)  8GB Cache w standardzie; 16GB (opcja)  Do 9 półek rozszerzeń  Do 240 dysków 2,5'' lub 120 dysków 3,5''  Do 480TB pojemności  Możliwość mieszania dysków HDD/SSD w obudowie  Poziomy RAID: 0, 1, 5, 6, 10 Storwize V Charakterystyka

51 Storwize V3700: 2U-24 - widok z przodu

52 Storwize V3700: 2U-12 - widok z przodu

53  2x port iSCSI 1Gb/s Ethernet  4x port SAS 6Gb/s  2x port USB 2.0 Storwize V widok z tyłu

54  4x iSCSI 1Gb/s Ethernet  2x iSCSI/FCoE 10Gb/s Ethernet  4x Fibre Channel 8Gb/s  4x SAS 6Gb/s Karty rozszerzeń

55 Półka rozszerzeń V widok z tyłu

56 Small form-factor (SFF, 2.5-inch) HDD 15,000 RPM146GB, 300GB SAS 10,000 RPM600GB, 900GB, 1.2TB SAS 7,200 RPM1TB Nearline SAS Small form-factor (SFF, 2.5-inch) SSD200GB, 400GB, 800GB SAS Large form-factor (LFF, 3.5-inch) HDD 15,000 RPM300GB SAS 10,000 RPM900GB, 1.2TB SAS 7,200 RPM2TB, 3TB, 4TB Nearline SAS Obsługiwane dyski

57 Storwize V3700 – jak to działa? LAN Jeden sterownik multipathingu (SDD, MPIO) SAN Storwize V3700 Dyski wewnętrzne SSDSAS Storage Poole iSCSI, FC, FCoE, SAS Hosty Pool 1Pool 2 Vol1 Wolumeny NL-SAS Pool 3Pool 4 Vol2Vol3 Vol4Vol5

58  Wewnętrzna wirtualizacja Storage Pool MDyski Wolumeny Zaawansowana funkcjonalność

59  FlashCopy Zaawansowana funkcjonalność Źródło Aż do 64 kopii  Thin provisioning Zaalokowana przestrzeń bez funkcji thin provisioning Wykorzystywana przestrzeń z funkcją thin provisioning Dynamiczny wzrost

60  Skalowalność  Migracja danych Zaawansowana funkcjonalność Serwer aplikacji Storwize V3700Dotychczasowe dane Sieć

61  EasyTier  Remoty Copy  Turbo Performance Zaawansowana funkcjonalność IBM Storwize V3700 (dodatkowe opcje)  FlashCopy – do 2040 kopii Powyższe funkcjonalności można testować przez 90 dni w wersjach trialowych.

62 Storwize Family Hardware “Engines” Which is the Right Storwize Infrastructure Solution? IBM Storwize Family Software Efficient Easy Dependable 1. Sell SDS Value 2. Then Pick the “engine” required 4. Future scalability could determine right Engine choice 5. Values sold, can determine engine based on features required to deliver value Enabling clients to do more with less Half Price Data Storage 3x performance with only 5% Flash 47% less management effort 30% lower storage growth Performance. Efficiency. No compromises. 3. Match engine to budget Small  Internal Virtualization  Thin Provisioning  Data Migration  Advanced GUI  Multi Host support  VMware & MS Integr  FlashCopy (2040 Images)  EasyTier  Remote Mirror  Turbo Performance Up to 240 Drives $10,000 - $15,000 Medium V3700 plus…  Clustering (2)  Higher scalability  Higher Performance  Ext Virtualization Up to 480 drives $15,000 - $40,000 Large V5000 plus…  Clustering (4)  Higher scalability  Higher Performance  Compression  Unified Up to 1056 drives $40,000 - $100,000 Large Enterprise  Highest scalability  Highest Performance  Clustering  Thin Provisioning  Data Migration  Advanced GUI  Compression  Stretched Cluster  FlashCopy  EasyTier  Remote Mirror Up to 32PB* $40,000 - $100,000 *Requires external virtualised storage arrays. 62

63 Storwize V3700, Storwize V5000 and Storwize V7000 comparison Storwize V3700Storwize V5000Storwize V7000 Management SW Storwize V3700 machine code IBM Storwize family Software for Storwize V5000 IBM Storwize family Software for Storwize V7000 Capacity Up to 120 drives per control enclosure (up to 4 expansions) Up to 168 drives per control enclosure (up to 6 expansions); 336 per clustered system (two-way clustering) Up to 240 drives per control enclosure; 960 per clustered system (four clusters) Standard Host Ports 1Gb iSCSI, 6Gb SAS1Gb iSCSI, 6Gb SAS, FC1Gb iSCSI, FC Optional Host Ports iSCSI 10Gbps, FC, FCoEN/AiSCSI 10Gbps, FCoE Cache (dual ctl)8GB upgradeable to 16GB 16GB per dual controller, up to 32GB per clustered system 16GB per dual controller, up to 64GB per clustered system Integrated Features FlashCopy (64 images per system), Internal virtualization, Thin provisioning, Data Migration Internal virtualization, Thin Provisioning, Data Migration, System Clustering FlashCopy (4,096 images), Internal virtualization, Thin provisioning, Data Migration, Easy Tier, System Clustering Optional Features FlashCopy (2040 images) Remote Mirroring, Easy Tier, Turbo Performance FlashCopy (4,096 images) Easy Tier, Remote Mirroring, External Virtualization Remote Mirroring, Real Time Compression, External Virtualization External Virtualization NoYes, Optional Unified SupportNo NAS connectivity with Storwize V7000 Unified; IBM Active Cloud Engine integrated

64 Pytania?

65 Dziękuję


Pobierz ppt "Maciej Michno IBM Systems Engineer Mobile: 605 821 729."

Podobne prezentacje


Reklamy Google