Pobieranie prezentacji. Proszę czekać

Pobieranie prezentacji. Proszę czekać

IBM Storwize Family Maciej Michno IBM Systems Engineer

Podobne prezentacje


Prezentacja na temat: "IBM Storwize Family Maciej Michno IBM Systems Engineer"— Zapis prezentacji:

1 IBM Storwize Family Maciej Michno IBM Systems Engineer
Mobile:

2 Agenda Rodzina IBM Storwize IBM SAN Volume Controller
IBM Storwize V7000 Gen2 IBM Storwize V5000 IBM Storwize V3700

3 IBM System Storage Portfolio - 2014
Centralne zarządzanie heterogenicznym środowiskiem pamięci masowych Backup, Recovery, Archiwum, Rozwiązania optymalizacyjne Tivoli Productivity Center (TPC) Tivoli Storage Manager (TSM) Virtual Storage Center (VSC) Serwery plików i systemy Unified ProtecTIER - Deduplication Real-Time Compression Systems Director – Storage Control Large Enterprise SONAS Wirtualizacja Pamięci Masowych Entry–>Enterprise N Series Storage Area, CEE, & iSCSI Networks Brocade, CISCO, Juniper, BNT Entry -> Low-Mid Opcja NAS V7000 V7000U SAN Volume Controller (SVC) Zintegrowane środowisko wirtualizacyjne Pamięć blokowa Non-IBM DS8870 Enterprise XIV Gen3 EMC Zielony backup i archiwum Taśmy HP Midrange StorwizeV7000 V5000 Flash Sys HDS Others Entry StorwizeV3700 DS3500 DCS3860 Inne macierze 3

4 Rodzina Storwize Wspólna platforma programowa (kod)
SAN Volume Controller 06/2003 Wspólna platforma programowa (kod) Spójny zestaw funkcjonalności Zunifikowane zarządzanie (GUI i konsola) Flex System V7000 11/2012 Storwize V7000 Unified 10/2011 Storwize V7000 10/2010 Storwize V5000 10/2013 Storwize V3700 11/2012

5 Struktura logiczna 5

6 Struktura logiczna B8 A2 A6 B1 B5 A3 A7 B2 B6 A4 A8 B3 B7 A1 A5 A9 B4
Volume A Volume B Volumes Managed Disks Thin Provisioned Volume C C1 C2 C3 C4 C5 C6 C7 C8 Storage Pool 6

7 Wirtualizacja pamięci masowych
VD 7 VD 6 Volume VD 4 VD 5 VD 1 VD 2 VD 3 Wirtualizator Storage Pool MDisks Szybkie Duże MD 1 MD 2 MD 3 MD 4 MD 5 MD 6 MD 7 MD 8 LUN 1 LUN 2 LUN 3 LUN 4 LUN 1 LUN 2 LUN 3 LUN 4 SCSI LUNs Kontroler RAID Kontroler RAID 7

8 Korzyści wirtualizacji – lepsza utylizacja przestrzeni dyskowej
Tradycyjny SAN Pojemność jest izolowana na wyspach SAN Wiele punktów zarządzania Niska utylizacja dysków SVC/ Storwize V7000 / V5000 Pojemność jako wspólny zasób Lepsze wykorzystanie pojemności Jeden punkt zarządzania SAN SAN 55% 95% 50% 25% Storwize V7000

9 Ciągła migracja danych
Tradycyjny SAN Zatrzymanie aplikacji Przeniesienie danych Ponowne udostępnienie danych Restart aplikacji Zwirtualizowane środowisko Przenosimy dane Host nie widzi przerwy w dostępie do danych SAN SAN Storwize V7000

10 Uproszczenie administracji – serwisy kopiujące
Tradycyjna sieć SAN Różne serwisy replikujące różne macierze Macierz docelowa musi być tego samego typu co źródłowa Tańsze macierze bez replikacji Wirtualizator Pamięci Masowej Wspólne serwisy kopiujące i replikujące w całej sieci SAN niezależne od macierzy Można replikować dane na macierze tańsze obniżając koszty replikacji SAN FlashCopy® Metro/Global Mirror TimeFinder SRDF SAN wirtualizator wirtualizator 10 IBM DS5000 IBM DS5000 EMC DMX HDS AMS IBM HP EVA EMC Clariion IBM EMC DMX 10

11 Volume Mirroring Storwize przechowuje dwie kopie Volumenu
Storwize V7000 Storwize przechowuje dwie kopie Volumenu Jeśli jedna kopia przestanie działać Storwize umożliwia dostęp do danych z drugiej kopii Automatyczna resynchronizacja Lokalne HA Kopie mogą zostać rozdzielone Każda kopia może stać się produkcyjna Copy 1 Copy 0

12 Thin - Provisioning Wolność wyboru.. Wolumen w pełni zaalokowany
Wolumen „thin-prov” Swoboda zmiany.. Konwersja Thin na Full Konwersja Full na Thin 12

13 Flash Copy Backup, Recovery, Testy, Kopie systemów
Do 256 Kopii Flash Copy Backup, Recovery, Testy, Kopie systemów Kopie migawkowe (Snapshoty) Kopie pełne (Clone) Kopie przyrostowe (Backup) Kopie kaskadowe (kopia z kopii) Target Source OR Target 2. Reverse FlashCopy Source

14 Bezpieczeństwo danych
Lokalny mirror Dwie niezależne kopie HA w obrębie lokalizacji FlashCopy Migawki wolumenów Kopie na inne systemy dyskowe Metro Mirror Replikacja synchroniczna Global Mirror Replikacja asynchroniczna Vol0 Vol0’ Vol0’ R W W Storwize V7000 Storwize V7000 System Dyskowy System Dyskowy’ System Dyskowy

15 Benefity optymalizacji - IBM Easy Tier
SSD HDD SSD HDD Automatyczna relokacja Hot-spoty Zoptymalizowana wydajność Technologia, która się uczy Optymalizacja polegająca na umieszczeniu „gorących” danych na dyskach SSD Trójwarstwowy, w pełni automatyczny mechanizm optymalizacyjny Efekt: wzrost IOPS, spadek RT

16 Easy Tier – automatyczna relokacja fragmentów danych na podstawie obciążenia
Pula extentów Easy Tier Wolumen Logiczny Wirtualizacja – podział na extenty SSD Dane „ zimne” Dane „gorące” Easy Tier monitoruje wydajność każdego z extentów aby ustalić ‘temperaturę” danych Easy Tier tworzy plan migracji extentów dla optymalizacji ułozenia danych co 24 godziny Easy Tier migruje extenty zgodnie z planem w ciągu 24 godzin (ograniczona ilość extentów jest migrowana co każde 5 minut) Now, this is a very simple illustration, but it gives you a good idea about how Easy Tier works. The hottest 1GB segments (extents) move up to the SSDs, while the cooler segments move down to the slower HDDs. Easy Tier monitors performance of each extent to determine the data ‘temperature’ It then creates an extent migration plan for optimal data placement every 24 hrs based on performance statistics Next, it migrates extents within an the Easy Tier extent pool according to plan over 24 hour period by migrating a limited number of extents every 5 minutes. This is to prevent affecting current workloads throughout the 24- hour migration period. HDD Wolumeny logiczne

17 Easy Tier 3 Now supports two or three tiers
Flash + 2 disk tiers Flash + 1 disk tier 2 disk tiers Deploy flash and enterprise disk for performance Grow capacity with low cost disk Storwize V7000 moves data automatically between tiers Available on all systems licensed for Easy Tier No additional charge Flash Arrays HDD Arrays Active Data Migrates Up Less Active Data Migrates Down

18 Easy Tier 3 STAT Tool Provides recommendations on adding additional tier capacity and performance impact Tier 0: Flash Tier 1: “Enterprise” disk (15K and 10K) Tier 2: Nearline disk (7.2K)

19 Kompresja Kompresja jest zaimplementowana jako trzeci typ wolumenów
Wspierane te same funkcje co dla Thin-Provisioning (takie jak autoexpand…) GUI wyswietla oszczedności wynikające z zastosowania kompresji

20 Współczynnik kompresji
Storage after Compression Compression Ratio 100% 80% 60% 2.5x mniej pojemności 3.3x szybsza replikacja 3.5x skrócenie RTOs 40% 6.6x szybsze backupy 20% do 60% 20% 70.0% 72.0% 85.0% 0% Dane użytkowników CAD/CAM Engineering Bazy danych Serwery wirtualne 20

21 Kompresja monitoring GUI wspiera rozdzielenie monitoringu CPU dla kompresji

22 Graficzny interfejs użytkownika (GUI)
22

23 New SVC Engine More powerful hardware platform One or two 8-core CPUs
2x performance of SVC CG8 engine Up to 9x compressed performance One or two 8-core CPUs 32GB cache per CPU (32GB or 64GB of cache per engine) More flexible server connectivity Industry first hardware compression acceleration with Intel QuickAssist technology One or two optional accelerators Provide dedicated processing power and greater throughput for compression Integrated flash capability: up to 48 12Gbps flash drives In external flash expansion enclosures

24 New SVC Engine 2145 Model DH8 New 2U form factor
Internal batteries eliminate need for UPS Total system size unchanged Up to 3 I/O adapter cards 8Gbps FC 10Gbps FCoE/iSCSI 1 Gbps iSCSI 4 3 8 12 Expansion slots Technician IP port 1Gb iSCSI Dual PSUs

25 SVC Configuration Rules
At least one compression accelerator is required to use Real-time Compression Optional second CPU and 32GB memory required When using Real-time Compression When 3 host interface cards are installed Three FC interface cards or two FC interface cards and one 10GbE card Optional second CPU and memory may be installed now in anticipation of future use (see SODs) Both engines in an I/O Group must be configured the same

26 New SVC Flash Expansion
One or two SVC SFF Expansion Enclosures F No other expansion enclosure supported Attach to both nodes in an I/O Group Requires 12Gbps SAS Enclosure attach card in both Up to GB, 400GB, or 800GB 12Gbps flash drives Up to 38.4TB raw capacity Disk drives are not supported Flash may be used for dedicated volumes or with Easy Tier

27 SVC Investment Protection
New SVC engines may be added to existing SVC systems without disruption New SVC engines may replace existing engines in SVC systems without disruption All engines in an SVC system may access flash expansion capacity SVC system must be running Version 7.3 software

28 SVC Maximum Performance (One I/O Group)
Uncompressed SVC CG8 New SVC DH8 Read Hit IOPS 1,000,000 1,500,000 Read Miss IOPS 360,000 630,000 Write Miss IOPS 125,000 200,000 “DB-like” 385,000 Compressed SVC CG8 New SVC DH8 Read Miss IOPS 2,600-50,000 71, ,000 Write Miss IOPS 1,200-16,000 28, ,000 “DB-like” 2,200-40,000 59, ,000 Compressed performance shows a range depending on I/O distribution Compressed performance is better than uncompressed in some cases because of fewer I/Os to drives and additional cache benefits Preliminary data: Subject to change before GA

29 New SVC Data Engine Power to Virtualize
Virtualized server environments demand virtualized storage 2x performance: up to 128 cores 50% more connectivity: up to 96 FC ports 2.5x cache: up to 512GB 6x integrated flash: up to 192 drives

30 New Storwize V7000 More powerful hardware platform
2x performance of previous Storwize V7000 Compressed performance comparable or better than uncompressed previous Storwize V7000 More flexible server connectivity Up to 8x cache: 32GB or 64GB cache per controller (64GB or 128GB per control enclosure) Industry first hardware compression acceleration with Intel QuickAssist technology One accelerator standard, second optional Provides dedicated processing power and greater throughput for compression Cache upgrade required when using second compression accelerator Double scalability: Up to 20 expansion enclosures Up to 504 SFF drives or 240 LFF drives per system Up to 1056 SFF drives or 960 LFF drives per clustered system 12 Gbps SAS connectivity

31 New Storwize V7000 Control Enclosure
Available only in 2.5-inch drive model Flexible interface options One standard, optional second compression accelerator Technician IP port replaces USB key configuration Ports per System 8Gbps FC 10Gbps FCoE/iSCSI 1 Gbps iSCSI 8 6 16 SAS expansion ports 1GbE ports Compression accelerator slot Host interface slots Technician IP port PSU PSU Dual controller canisters

32 New Storwize V7000 Expansion Enclosure
Available in 2.5- and 3.5-inch drive models 2076 Models 12F and 24F Attaches to new control enclosure using 12Gbps SAS Mix drives within enclosure, including different drive speeds Mix enclosure types in a system All drives dual ported, hot swappable 2.5-inch Flash Drives 200GB, 400GB, 800GB Flash 12Gbps 2.5-inch High Performance Drives 300GB, 600GB SAS, 15K RPM 600GB, 900GB, 1.2TB SAS, 10K RPM 6Gbps 1TB NL-SAS, 7.2K RPM 3.5-inch High Capacity Drives 2TB, 3TB, 4TB

33 New Storwize V7000 Expansion
Up to 20 expansion enclosures per control enclosure In a clustered system, software supports maximum of 1056 drives Enables fully populated LFF system (4PB raw capacity) Exceeds needs of almost all customers using SFF drives Previous expansion enclosures and drives cannot attach to new control enclosures Protect investments and migrate data by mixing old and new systems in a clustered system

34 New Storwize V7000 Power and Scalability for All Your Data
2x scalability: up to 4PB 2x performance: up to 64 cores 2x infrastructure speed: 12Gbps SAS 2x connectivity: up to 64 FC ports 8x cache: up to 512GB

35 V7000 Unified – NAS V7000 Unified

36 Storwize Family Software Version 7.3
Supports new Storwize V7000 and new SVC engine Supports additional expansion for Storwize V3700 and Storwize V5000 Both systems now support up to 9 expansion enclosures Easy Tier 3 Storage Pool Balancing Improved licensing model for Storwize V7000 and Storwize V5000

37 IBM Storwize V7000 Storwize V7000 – nowoczesny system dyskowy klasy midrange. Posiada funkcjonalnośc wirtualizacji wewnętrznej i zewnętrznej przestrzeni dyskowej Bazuje na technologii SVC Wykonany w architekturze SAS Pełna redundancja 8GB pamięci cache per kontroler– (per macierz 16GB pamięci cache) Interfejsy dysków 8 portów 8 Gbps FC 4 porty 1 Gbps iSCSI 4 porty 10 Gbps iSCSI Instalacja i wymiana komponentów u klienta Wszystkie elementy są wymienialne na „gorąco”

38 Storwize V7000 – widok z przodu i z tyłu
Obudowa – 12 x 3.5” LFF /212 Obudowa – 24 x 2.5” SFF /224 8Gbps FC 10Gbps iSCSI/FCoE 1Gbps iSCSI

39 Modularna budowa Początek z półką kontrolerów
Do 9 półek rozszerzeń na jedną parę kontrolerów Mieszanie półek 2.5” & 3.5” Mieszanie rodzajów dysków w ramach każdej półki Możliwość dodawania kolejnych par kontrolerów Półki kontrolerów Control Enclosures

40 Storwize V7000 – dyski 2,5’’ 3,5’’ 146GB 15K 2TB 7200
2,5’’ 3,5’’ 146GB 15K 2TB 7200 300GB 15K 3TB 7200 300GB 10K TB 7200 600GB 10K 900GB 10K 1.2TB 10K 1TB 7200 200GB SSD 400GB SSD 800GB SSD

41 Storwize V7000 - Licencjonowanie
Thin Provisioning FlashCopy Easy Tier Metro and/or Global Mirror – Opcjonalnie External Virtualization – Opcjonalnie Kompresja - Opcjonalnie

42 Storwize V5000 - Charakterystyka
Obudowa Storwize V5000 o wysokości 2U: 2x kontroler (NOD) 16GB Cache w standardzie Do 9 półek rozszerzeń Do 240 dysków 2,5'' lub 120 dysków 3,5'' Do 480TB pojemności Możliwość mieszania dysków HDD/SSD w obudowie Poziomy RAID: 0, 1, 5, 6, 10 42

43 Storwize V5000 - widok z przodu
43

44 Storwize V5000 - widok z tyłu
2x port iSCSI 1Gb/s Ethernet 4x port SAS 6Gb/s 4x Fibre Channel 8Gb/s lub 2x 10Gbps iSCSI/FCoE SAS Disk Expansion Ports Mgmt and 1Gbps iSCSI 4x 8Gbit Fibre Channel SAS Host Attach Ports Power input cables 44

45 Półka rozszerzeń V5000 - widok z tyłu
SAS Disk Expansion In Ports SAS Disk Expansion Out Ports Power input cables 45

46 Storwize V5000 - Łańcuch SAS
6 Chain 2 Expansion Enclosures 4 2 Control Enclosure 1 Chain 1 Expansion Enclosures 3 5 46

47 Połączenie z hostami poprzez switch FC
47

48 Połączenie bezpośrednie z hostami po FC
48

49 Storwize 5000 - Licencjonowanie
Internal Virtualization Data Migration System Clustering Thin Provisioning FlashCopy – Opcjonalnie Easy Tier – Opcjonalnie Remote Mirroring – Opcjonalnie External Virtualization – Opcjonalnie

50 Storwize V3700 - Charakterystyka
Obudowa Storwize V3700 o wysokości 2U: 2x kontroler (NOD) 8GB Cache w standardzie; 16GB (opcja) Do 9 półek rozszerzeń Do 240 dysków 2,5'' lub 120 dysków 3,5'' Do 480TB pojemności Możliwość mieszania dysków HDD/SSD w obudowie Poziomy RAID: 0, 1, 5, 6, 10 50

51 Storwize V3700: 2U-24 - widok z przodu
51

52 Storwize V3700: 2U-12 - widok z przodu
52

53 Storwize V3700 - widok z tyłu
2x port iSCSI 1Gb/s Ethernet 4x port SAS 6Gb/s 2x port USB 2.0 53

54 Karty rozszerzeń 4x iSCSI 1Gb/s Ethernet 2x iSCSI/FCoE 10Gb/s Ethernet
4x Fibre Channel 8Gb/s 4x SAS 6Gb/s 54

55 Półka rozszerzeń V3700 - widok z tyłu
55

56 Obsługiwane dyski Small form-factor (SFF, 2.5-inch) HDD 15,000 RPM
146GB, 300GB SAS 10,000 RPM 600GB, 900GB, 1.2TB SAS 7,200 RPM 1TB Nearline SAS Small form-factor (SFF, 2.5-inch) SSD 200GB, 400GB, 800GB SAS Large form-factor (LFF, 3.5-inch) HDD 300GB SAS 900GB, 1.2TB SAS 2TB, 3TB, 4TB Nearline SAS 56

57 Storwize V3700 – jak to działa?
Hosty Jeden sterownik multipathingu (SDD, MPIO) iSCSI, FC, FCoE, SAS LAN SAN Wolumeny Storwize V3700 SSD SAS SAS NL-SAS Pool 1 Pool 2 Pool 3 Pool 4 Vol1 Vol2 Vol3 Vol4 Vol5 Storage Poole Dyski wewnętrzne

58 Zaawansowana funkcjonalność
Wewnętrzna wirtualizacja Wolumeny Storage Pool MDyski 58

59 Zaawansowana funkcjonalność
FlashCopy Aż do 64 kopii Źródło Thin provisioning Zaalokowana przestrzeń bez funkcji thin provisioning Wykorzystywana przestrzeń z funkcją thin provisioning Dynamiczny wzrost 59

60 Zaawansowana funkcjonalność
Skalowalność Migracja danych Serwer aplikacji Sieć Dotychczasowe dane Storwize V3700 60

61 Zaawansowana funkcjonalność IBM Storwize V3700 (dodatkowe opcje)
EasyTier Remoty Copy FlashCopy – do 2040 kopii Turbo Performance Powyższe funkcjonalności można testować przez 90 dni w wersjach trialowych. 61

62 Which is the Right Storwize Infrastructure Solution?
IBM Storwize Family Software Efficient Easy Dependable 1. Sell SDS Value Enabling clients to do more with less Half Price Data Storage 3x performance with only 5% Flash 47% less management effort 30% lower storage growth Performance. Efficiency. No compromises. Storwize Family Hardware “Engines” 2. Then Pick the “engine” required V3700 V5000 V7000 SVC 3. Match engine to budget Small Internal Virtualization Thin Provisioning Data Migration Advanced GUI Multi Host support VMware & MS Integr FlashCopy (2040 Images) EasyTier Remote Mirror Turbo Performance Up to 240 Drives $10,000 - $15,000 Medium V3700 plus… Clustering (2) Higher scalability Higher Performance Ext Virtualization Up to 480 drives $15,000 - $40,000 Large V5000 plus… Clustering (4) Higher scalability Higher Performance Compression Unified Up to 1056 drives $40,000 - $100,000 Large Enterprise Highest scalability Highest Performance Clustering Thin Provisioning Data Migration Advanced GUI Compression Stretched Cluster FlashCopy EasyTier Remote Mirror Up to 32PB* $40,000 - $100,000 4. Future scalability could determine right Engine choice So now we have an understanding of the enhanced value Storwize delivers with its Software Defined Storage and new hardware infrastructure choices, how do we position with is the right one? We need to focus on the value of the Storwize software. This what we need to sell. Ensure customers understand the value on the three keys areas; Storwize is Efficient, easy & dependable All the points we have just covered. Once we have our customers bought into our Software Defined Storage value, that we have the infrastructure that matters, we need to help them pick the right engine to run it. Very similar to how customers choose an application, and then choose the server platform to run it. It could well be their budget, or their future scalability that determines the right engine for their environment. Or if they are particularly sold on a couple of specific features, again that will help narrow in on the right “engine” to propose. Focusing on the Storwize software value, and articulating these values is the key. Some competitors have inefficient code running on their storage devices, requiring high specification hardware, with larger processors, larger cache etc.. They will then try to turn the debate, or set the agenda with the customer, that hardware spec comparisons are the key measurement to determining the right solution. With these new engines, we do not be afraid of such comparisons, but to allow this to become the focus, it to sell our systems short. We must sell the value of Storwize. Ensure our customers understand the value Storwize brings. How much more efficient, easy and dependable it is, to address their issues with data growth, administrative burden and providing an always-on environment, ultimately leading to more projects being delivered on-time and within budget. Please also note, as part of this announcement, Storwize V5000 scalability is increased. Customers, both existing and new, can now scale these systems to 480 drives, up from the previous maximum of 336. 5. Values sold, can determine engine based on features required to deliver value *Requires external virtualised storage arrays.

63 Storwize V3700, Storwize V5000 and Storwize V7000 comparison
Management SW Storwize V3700 machine code IBM Storwize family Software for Storwize V5000 IBM Storwize family Software for Storwize V7000 Capacity Up to 120 drives per control enclosure (up to 4 expansions) Up to 168 drives per control enclosure (up to 6 expansions); 336 per clustered system (two-way clustering) Up to 240 drives per control enclosure; 960 per clustered system (four clusters) Standard Host Ports 1Gb iSCSI, 6Gb SAS 1Gb iSCSI, 6Gb SAS, FC 1Gb iSCSI, FC Optional Host Ports iSCSI 10Gbps, FC, FCoE N/A iSCSI 10Gbps, FCoE Cache (dual ctl) 8GB upgradeable to 16GB 16GB per dual controller, up to 32GB per clustered system 16GB per dual controller, up to 64GB per clustered system Integrated Features FlashCopy (64 images per system), Internal virtualization, Thin provisioning, Data Migration Internal virtualization, Thin Provisioning, Data Migration, System Clustering FlashCopy (4,096 images), Internal virtualization, Thin provisioning, Data Migration, Easy Tier, System Clustering Optional Features FlashCopy (2040 images) Remote Mirroring, Easy Tier, Turbo Performance FlashCopy (4,096 images) Easy Tier, Remote Mirroring, External Virtualization Remote Mirroring, Real Time Compression, External Virtualization External Virtualization No Yes, Optional Unified Support NAS connectivity with Storwize V7000 Unified; IBM Active Cloud Engine integrated

64 Pytania?

65 Dziękuję


Pobierz ppt "IBM Storwize Family Maciej Michno IBM Systems Engineer"

Podobne prezentacje


Reklamy Google